| Model | 70 psi | 80 psi | 90 psi | 100 psi |
|---|---|---|---|---|
| G400-40-50 (4″) | 698 | 851 | 997 | 1,072 |
| G400-40-150 (4″) | 1,070 | 1,220 | 1,383 | 1,532 |
| G400-60-300 (6″) | 1,735 | 2,000 | 2,320 | 2,525 |
| G400-60-650 (6″) | 2,065 | 2,380 | 2,761 | 3,005 |
Blast force in pounds by charge pressure. Designed for high-temperature environments, safety-smart isolation valve included, no lubrication, 5-year warranty.
| Application | Typical setup | Notes |
|---|---|---|
| Chutes & transfer buildup | Smaller tanks, fan-jet nozzles | Frequent light shots beat rare heavy ones |
| Silo cone / bridge zone | Mid-size tanks just above the arch line | Sequence upward — bottom cannon first |
| Rathole shoulders | Array around the walls, sequenced | Placement > blast force, every time |
| Preheater / high-temp process | High-temp valves and piping | Standard seals die young up there — spec for it |
| Symptom | Likely cause | Fix |
|---|---|---|
| Won’t fire | Solenoid, signal or stuck valve | Verify pilot air and signal; rebuild kit |
| Weak shot | Supply pressure low or fill leak | Gauge at the tank; fix the leak before upsizing anything |
| Constant hiss | Exhaust or check valve leaking | Service kit — it’s eating compressed air daily |
| Fires but buildup returns fast | Wrong placement/sequence for the flow pattern | Re-aim the array — see the rathole-vs-bridge guide |
Yes — QEVs, o-rings, gaskets and safety cables for most major brands. A nameplate photo is usually all we need to match parts.
Ordinary plant air, 70–100 psi. Force rises with pressure — the table above shows the spread by model.
Mounting requires a welded nozzle assembly on the vessel — a planned job with hot-work controls. Many customers weld the nozzle to our spec and we handle the rest; full installation service is available.
Reading about it is free. So is the phone call. Some answers only come from climbing into the equipment — that’s the part we do in person. Tell us the plant, the part and the problem, and you’ll get a real person.
Browse air cannon parts →Or call (888) 480-0680 · sales@groupactinc.com · Serving CA, NV, OR & WA since 1991.
Applied Conveyor Technology — bulk material handling experts. Dust control, conveyor services, silo cleaning, parts, and engineering.
909-350-4703
888-480-0680 (toll-free)
© 2026 The ACT Group (Applied Conveyor Technology). All rights reserved.