The Stockpile · Pile 03 — The Fix List
A customer asked us to run their compliance source test. We had to say no. The rules behind that no are ones every California plant should know.
A customer we’ve done baghouse work for called with what sounded like an easy ask: their source test was coming up, we knew the collector better than anyone, could we just run the test? From where they sat it made perfect sense. One vendor, one visit, one invoice.
We had to tell them no — and not because we lack the instruments or the people. California’s air rules are written specifically so that the company that installs or services your emission control equipment cannot be the company that certifies it. Not with a different crew, not under a different name, not as a favor. We looked hard at this, because testing seemed like a natural thing to add. The rules say otherwise, and once you read them, you’ll be glad they do.
Two separate regulators draw the line, and they draw it in slightly different places. Both apply to most industrial plants in the state.
| Rule | What it says | What it means for you |
|---|---|---|
| South Coast AQMD Laboratory Approval Program, No Conflict of Interest Statement, clause 4 | The test facility shall not be in partnership with, own, or be owned by — in any part or in full — the contractor who provided or installed equipment (basic or control) or monitoring systems for the company being tested. | It’s an ownership test, not a project test. A separately branded testing arm of your equipment vendor still fails it. In the South Coast district, your installer is out, full stop. |
| CARB 17 CCR §91208, Conflict of Interest | A tester is disqualified if it manufactured or installed any emission control device or monitor on the specific source being tested — or if, in the 12 months before the test, it received more than $100,000 (or more than 10% of its own revenue) from the facility for anything other than source testing. Common ownership counts. | Statewide, the installer of that baghouse is out. And any contractor who did more than $100K of work for your plant last year is out too, even if they never touched the collector being tested. |
Read those together and the picture is clear. The firm that sells you a baghouse, rebuilds it, changes the bags, or does meaningful work anywhere on your site is, by design, not allowed to be the firm that tells the air district it passes. The testing business is a pure-play business, and the firms that do it well stay that way on purpose.
It’s tempting to read this as bureaucracy. It isn’t. A source test is the one document standing between your plant and a notice of violation, a permit condition, or a shutdown. The regulator needs to trust it, your insurer needs to trust it, and when something goes wrong, your attorney needs to trust it. A test run by the people who built the thing being tested is a test nobody can fully trust — not because anyone would cheat, but because nobody could prove they didn’t.
So here is the practical takeaway, and it cuts against our own interests: if an equipment vendor offers to certify their own installation, that is a reason to be careful with that vendor. Either they don’t know the rules, or they’re hoping you don’t. The honest answer to “can you test it?” from anyone who installed it is no.
Three credentials matter, and depending on where your plant is, you may need to see two of them.
The questions to put to any testing firm before you book: Which CARB Executive Order number do you hold, and when does it expire? Are you LAP-approved for the specific method my permit requires? Who is the QSTI on my job? Those three answers tell you everything.
These firms appear on CARB’s approved independent contractor list as of this writing. We don’t have a financial relationship with any of them — which, after reading the section above, you’ll understand is the point. Approvals expire and renew, so confirm current status on the CARB list and, for South Coast work, the SCAQMD LAP list before you sign.
For Nevada plants, Broadbent & Associates in Henderson also holds CARB approval, and several of the Bakersfield and Southern California firms travel.
Here is what we can do, and it’s where most of the money and the stress actually lives. Tests rarely fail on the day because of the stack gas. They fail, or get postponed at full day-rate, because of everything around it.
Many of our customers have us coordinate the whole thing: we get the stack ready, an independent firm pulls the samples, and if the numbers come back wrong, we’re already on site with the parts. That arrangement is common, it’s clean under both rules, and it keeps one phone number on the problem.
Ports, platforms, pre-test surveys, and the repairs that turn a failed test into a passed retest — from Fontana, across California and Nevada.
Baghouse & dust collector service →Not in California. South Coast’s rule is an ownership test — any firm the installer owns in whole or in part is barred. CARB’s rule bars the installer of that specific device, and separately bars anyone who did more than $100,000 of non-testing work for your plant in the prior twelve months, with common ownership counted together.
If they billed you more than $100,000 (or more than 10% of their own revenue) in the last year for anything other than source testing, yes — under 17 CCR §91208 they’re disqualified for that plant, even if they never touched the baghouse being tested.
Inside the South Coast district, yes: CARB approval statewide plus LAP approval for the specific method your permit cites. Outside South Coast, most districts rely on CARB approval and their own test-protocol review. Your permit or the district’s source-test guidelines will say.
Six to eight weeks is comfortable; the district usually wants the test protocol submitted 30 days before the test date, and the good firms book out. Use the lead time for a port inspection and a pre-test traverse so the day isn’t a surprise.
No. We’ve quoted the rules and linked the sources so you can read them yourself. If a specific ownership or contracting arrangement is riding on the answer, get a written read from an environmental attorney.
Tell us the date and the method on your permit. We’ll check the ports, run a traverse, and make sure the only thing the testing crew finds is a collector that passes. Since 1991. Call (888) 480-0680 or write sales@groupactinc.com.
Talk to a human →Applied Conveyor Technology — bulk material handling experts. Dust control, conveyor services, silo cleaning, parts, and engineering.
909-350-4703
888-480-0680 (toll-free)
Industrial Services
Industrial Parts
About Us
Blog
Contact
Service Areas
Silo Cleaning: Inland Empire · Los Angeles · Central Valley · Nevada
Dust Collection: Inland Empire · Los Angeles
Belt Vulcanizing: Los Angeles · Nevada
© 2026 The ACT Group (Applied Conveyor Technology). All rights reserved.